Where a container is heated or cooled through a jacket (Fig. B)

Where a container is heated or cooled through a jacket (Fig. B)

(Summary description)

Where a container is heated or cooled through a jacket (Fig. B)

(Summary description)

Information

(Example 1) Minimum permissible temperature (Tj<TW) for injection of cold liquid into a jacket of a hot con-
tainer(Tw=200°℃)
Step:
1. Find out the wall temperature Tw = 200℃ on the abscissa axis of Figure B.
2. Draw a vertical line along the dot at 200C and intersect it at the edge of the blue area.
3. Make a horizontal line parallel to the abscissa and intersect the Tj points on the longitudinal coordinates.
Tjmin = 65°℃
(Example 2) Maximum permissible temperature (Tj> TW) for hot liquid injected into the jacket of a hot con-
tainer (Tw=30°℃)
Step:
1. Find out the wall temperature Tw = 30C on the abscissa axis of Figure B.
2. Draw a perpendicular line along the dot at 30C and intersect it at the edge of the red area.
3. Make a horizontal line parallel to the abscissa at the intersection point, which is comparable to the Tj point
on the longitudinal coordinate. Tjmax = 170℃

Scan the QR code to read on your phone

Recommended news

Zibo Yongzheng Chemical Equipment Co., Ltd.

Have questions or suggestions?

wangdong@zbyongzheng.com

Zibo Yongzheng Chemical Equipment Co., Ltd.

National Service Hotline:+86-18953371519

Monday to Sunday: 7:30-17:00

Zibo Yongzheng Chemical Equipment Co., Ltd.

After-sales service

Your satisfaction drives us forward

About us

The company mainly produces glass-lined equipment, first- and second-class carbon steel, stainless steel non-standard pressure vessels and glass-lined equipment maintenance and firing.

Address: No.162, Shanquan Road, Zhangdian District, Zibo City, Shandong Province

Username used for comment:
客户留言
Description:

Copyright © Zibo Yongzheng Chemical Equipment Co., Ltd.  国际站建设:中企动力 淄博